Functional and Structural Assessment of Endobronchial Valve Recipients Using Dynamic Hyperpolarized Xenon-129 MRI
Model scores of the 29,894 trials active now.
Model score 18% for any early termination, 4% for termination due to slow enrollment. Past trials like this one (phase, sponsor type and disease area, started 2008–2016) ended terminated 6% of the time (355 trials).
Finished trial that started in 2015 or later: the model never saw it during training.
How it ended
Terminated on 2025-09-11, after 2023-10-20 start.
Reason given by the sponsor: “other”
The score above never used this outcome: finished trial that started in 2015 or later: the model never saw it during training.
Termination over time, as the model saw it at the start
Cumulative chance of ending terminated (red) or completed (green) by each year from its start; it actually ended on 2025-09-11. The rest of the way to 100% is still running.
From the competing-risks survival model (termination vs completion, still-running trials censored), fit to trials that started 2008–2014 and recalibrated to termination rates over 2022–2024, since termination has become more common. Checked on past years, it still ran a little low when the rise continued.
What moved the score
-
Wording of the registration (title, summary, criteria) (raises risk) · Wording
Phrases that raised it: mrifailureimaginglungtherapy
Phrases that lowered it: alcoholexaminationthe studyinterfere withpatients who -
Sponsor's past termination rate: 0% (lowers risk) · Sponsor's track record
-
Accepts healthy volunteers: No (raises risk) · Who can join
-
Phase: 1 (lowers risk) · Design
-
Primary purpose: diagnostic (lowers risk) · Design
-
Trials the sponsor started in the prior 2 years: 1 (raises risk) · Sponsor's track record
-
Design: single group (raises risk) · Design
-
Minimum age: 18 (raises risk) · Who can join
-
Disease area, cancer: No (lowers risk) · Disease area
-
Maximum age: 85 (lowers risk) · Who can join
-
Drug's FAERS reports with a death: no FAERS history (raises risk) · Drug's FDA history
-
Sponsor type: industry (lowers risk) · Sponsor's track record
-
Number of arms: 1 (raises risk) · Design
-
Drug's FAERS reports marked serious: no FAERS history (raises risk) · Drug's FDA history
-
Collaborators: 1 (raises risk) · Design
Every input that moved this score, largest first: SHAP contributions in log-odds, red raising risk and green lowering it. They describe the model, not causes of termination. Phrases are traced from the text features back to this registration's words, approximately.
The trial
Design
- Phase
- 1 (typical: 2)
- Number of arms
- 1 (typical: 2)
- Allocation
- not applicable (typical: randomized)
- Design
- single group (typical: parallel)
- Primary purpose
- diagnostic (typical: treatment)
- Blinding
- none
- Has a data monitoring committee
- No (typical: 56% yes)
- Responsible party
- sponsor
- Collaborators
- 1 (typical: 0)
- Keywords listed
- 3 (typical: 1)
Who can join
- Minimum age
- 18
- Maximum age
- 85 (typical: 71)
- Sex
- all
- Accepts healthy volunteers
- No (typical: 9% yes)
Sponsor's track record
- Sponsor type
- industry (typical: academic or other)
- Sponsor's past trials
- 2 (typical: 32)
- Sponsor's past termination rate
- 0% (typical: 9.9%)
- Trials the sponsor started in the prior 2 years
- 1 (typical: 19)
Drug's FDA history
- Drugs with FDA adverse-event history
- 0 (typical: 1)
- Drug has FAERS history
- No (typical: 64% yes)
- Drug's FAERS reports before start
- 0 (typical: 2148)
- Drug's FAERS reports in the prior 12 months
- 0 (typical: 412.5)
- Drug's FAERS reports marked serious
- no FAERS history (typical: 85.6%)
- Drug's FAERS reports with a death
- no FAERS history (typical: 15.9%)
Disease area and drugs
- Disease areas
- respiratory
- Drugs matched to FDA substances
- none matched
Typical values are among the trials active now. Sponsor and drug history are counted only up to this trial's start date.
Similar finished trials
- MagniXene MRI Use in Patients With Asthma and COPD to Assess Regional Lung Function by Delineating Ventilation Defects NCT01833390 · started 2011 · scored riskier than 12% of active trials completed
- HP 129Xe MRI for Evaluation of CLAD in Lung Transplant Recipients NCT05550662 · started 2024 · scored riskier than 43% of active trials terminated
- Longitudinal MR Imaging of Pulmonary Function in Patients Receiving Thoracic Radiation Treatment NCT02478255 · started 2016 · scored riskier than 45% of active trials completed
- Effects of Bevespi on Ventilation and Gas Exchange Abnormalities in COPD Assessed by 129Xe MRI NCT03324607 · started 2018 · scored riskier than 54% of active trials completed
- Functional Applications of Hyperpolarized 129Xe MRI NCT01697332 · started 2013 · scored riskier than 29% of active trials terminated
Closest by meaning of the registration text (PubMedBERT embeddings), among finished trials. How they ended is context, not an input to this trial's score.